• pro-teso

    The perfect solution for railway sub-system control and monitoring. 20 years experience in HVAC, doors, fire protection, lighting and toilets.

    Read more
  • io-teso

    Expansion Modules are a flexible way to increase the I/O density of the pro-teso range of Programmable Controllers.

    Read more
  • com-teso

    Gateways to suit the application and the communications infrastructure available.

    Read more
  • Applications

    The Teso range of products are ideal for many sub-system applications.

    Read more

PC3012 PLC System for Rail Vehicles

PC3012 PLC System for Rail Vehicles

Product description

The PC3012 programmable controller offers a small size and 8 digital inputs with 8 digital outputs. RS232, RS485 and Ethernet come standard. IEC61131-3 or C programmable.
User Manual  

Product Specification

Input Voltage:+24 to +110 VDC
Environmental:Operational -40ºC to +85ºC, 5% to 95% Relative Humidity
Processor Speed:32 bit Digi NS9360 processor 155MHz (ARM926EJ-S)
SRAM Memory:512kB
FLASH Memory:4MB
Serial FLASH Memory:16MB
Backup Battery:Data RAM and RTC battery backed via 950mAH battery
Real Time Clock:Yes
Watchdog:CPU hardware watchdog
Digital Inputs:Eight (8) Fixed High Side Switch (Current Sinking) Nominal Close current: 7mA at 110Vdc inputs
Digital Outputs:Eight (8) Fixed High Side Switch (Current Sourcing) Maximum Load Current: 1.0A at 110Vdc
Ethernet:One (1) M12 Ethernet Port with Link and Activity LEDs
Serial Communications:One (1) RS232 port (5 wire) DB9 Female Connector One (1) Isolated RS485 port (3 wire) DB9 Female Connector One (1) Isolated RS232 port (5 wire) DB9 Female Connector
Protocol Support:Modbus TCP/IP Slave
Enclosure Material:Extruded Anodised Aluminium Enclosure
Enclosure Size:207 mm x 223 mm x 63 mm (including connectors
Compliance:EN50155:1996 – Compliance with Visual Inspection, Performance Test, Cooling Test, Dry Test, Supply Related Surge and Transient Susceptibility Test, Transient Burst Susceptibility Test and Vibration, Shock and Bump Test. All digital inputs and digital outputs comply with: Fast Electrical Transient Burst as per IEC61000-4-4 to ±2 kV with performance Criteria A. Direct Transient Burst as per IEC61000-4-5 to ±2kV with performance Criteria A. All analogue inputs comply with: Fast Electrical Transient Burst as per IEC61000-4-4 to ±2 kV with performance Criteria A.
Programming:ISaGRAF V5 - IEC61131-3 (SFC, FBD, LD, ST, IL, FC) or C